Water Utility

City of Converse

Location Converse, TX,
TX
Serves 29,709
PWS ID TX0150047

Overview

Contaminants Detected

This Utility: 0.638 ppb No Legal Limit
32x
EWG's Health Guideline:
0.02 ppb

Bromodichloromethane

Potential Effect: cancer
This Utility: 1.46 ppb No Legal Limit
24x
EWG's Health Guideline:
0.06 ppb
This Utility: 1.3 ppb No Legal Limit
2.6x
EWG's Health Guideline:
0.5 ppb

Chromium (hexavalent)*

Potential Effect: cancer
This Utility: 0.112 ppb No Legal Limit
5.6x
EWG's Health Guideline:
0.02 ppb
This Utility: 0.546 ppb No Legal Limit
18x
EWG's Health Guideline:
0.03 ppb

Dibromochloromethane

Potential Effect: cancer
This Utility: 2.36 ppb No Legal Limit
24x
EWG's Health Guideline:
0.1 ppb
This Utility: 0.871 ppb No Legal Limit
4.4x
EWG's Health Guideline:
0.2 ppb

Haloacetic acids (HAA5)

Potential Effect: cancer
This Utility: 1.61 ppb Legal Limit: 60 ppb
16x
EWG's Health Guideline:
0.1 ppb

Haloacetic acids (HAA9)*

Potential Effect: cancer
This Utility: 3.48 ppb No Legal Limit
58x
EWG's Health Guideline:
0.06 ppb

Nitrate

Potential Effect: cancer
This Utility: 0.948 ppm Legal Limit: 10 ppb
6.8x
EWG's Health Guideline:
0.14 ppb

Total trihalomethanes (TTHMs)

Potential Effect: cancer
This Utility: 6.66 ppb Legal Limit: 80 ppb
44x
EWG's Health Guideline:
0.15 ppb
This Utility: 129.3 ppb Legal Limit: 2000 ppb
EWG's Health Guideline:
700 ppb

Chloroform

Potential Effect: cancer
This Utility: 0.702 ppb No Legal Limit
EWG's Health Guideline:
0.4 ppb
This Utility: 1.08 ppm Legal Limit: 4 ppm
This Utility: 3.6 ppb No Legal Limit
This Utility: 13.2 ppb No Legal Limit
This Utility: 0.958 ppb No Legal Limit
EWG's Health Guideline:
100 ppb
This Utility: 1.76 ppb No Legal Limit
EWG's Health Guideline:
40 ppb
This Utility: 0.0979 ppb No Legal Limit
EWG's Health Guideline:
53 ppb
This Utility: 1.13 ppb No Legal Limit
EWG's Health Guideline:
1500 ppb

Trichloroacetic acid

Potential Effect: cancer
This Utility: 0.0958 ppb No Legal Limit
EWG's Health Guideline:
0.1 ppb
This Utility: 0.45 ppb Legal Limit: 20 ppb
EWG's Health Guideline:
0.43 ppb
This Utility: 2.16 ppb No Legal Limit
EWG's Health Guideline:
21 ppb
This Utility: 0.287 ppb Legal Limit: 10000 ppb
EWG's Health Guideline:
1800 ppb

Find a Filter

See which water filtration technologies are effective at reducing the contaminants detected in this utility's water supply.

Carbon Filters
Filters 9 contaminants exceeding guidelines (+5 others)

Can reduce the levels of many common contaminants.

Pros
  • Lower upfront cost
  • Reduced maintenance
Cons
  • Does not remove all contaminants
Reverse Osmosis
Filters 11 contaminants exceeding guidelines (+10 others)

Can reduce the levels of many common contaminants.

Pros
  • Most effective
Cons
  • Higher upfront cost
  • Requires more maintenance
  • Wastes water
Other Considerations
Ion Exchange
PROS: Softens hard water, Reduces some contaminants
CONS: Doesn't remove all contaminants
Whole-House Filters
PROS: Useful for reducing radiologicals and TCE
CONS: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants.

Contaminant Activated Carbon Reverse Osmosis Ion Exchange
Contaminants Above Health Guidelines
Bromochloroacetic acid
Bromodichloromethane
Bromoform
Chromium (hexavalent)*
Dibromoacetic acid
Dibromochloromethane
Dichloroacetic acid
Haloacetic acids (HAA5)
Haloacetic acids (HAA9)*
Nitrate
Total trihalomethanes (TTHMs)
Other Contaminants Detected
Barium
Chloroform
Fluoride
Hexadecanoic acid
Lithium
Manganese
Molybdenum
Monochloroacetic acid
Strontium*
Trichloroacetic acid
Vanadium*
Xylenes (total)

Protect your family's health.