Water Utility

Elyria Water Department

Location Lorain County, Ohio,
OH
Serves 68,000
Source Surface water
PWS ID OH4700411

Overview

Contaminants Detected

Bromodichloromethane

Potential Effect: cancer
This Utility: 9.39 ppb No Legal Limit
157x
EWG's Health Guideline:
0.06 ppb

Chloroform

Potential Effect: cancer
This Utility: 23 ppb No Legal Limit
57x
EWG's Health Guideline:
0.4 ppb

Chromium (hexavalent)*

Potential Effect: cancer
This Utility: 0.0906 ppb No Legal Limit
4.5x
EWG's Health Guideline:
0.02 ppb
This Utility: 0.751 ppb No Legal Limit
25x
EWG's Health Guideline:
0.03 ppb

Dibromochloromethane

Potential Effect: cancer
This Utility: 3.61 ppb No Legal Limit
36x
EWG's Health Guideline:
0.1 ppb
This Utility: 7.9 ppb No Legal Limit
40x
EWG's Health Guideline:
0.2 ppb

Haloacetic acids (HAA5)

Potential Effect: cancer
This Utility: 17.3 ppb Legal Limit: 60 ppb
173x
EWG's Health Guideline:
0.1 ppb

Haloacetic acids (HAA9)*

Potential Effect: cancer
This Utility: 26.3 ppb No Legal Limit
438x
EWG's Health Guideline:
0.06 ppb

Nitrate

Potential Effect: cancer
This Utility: 0.361 ppm Legal Limit: 10 ppb
2.6x
EWG's Health Guideline:
0.14 ppb
This Utility: 0.361 ppm Legal Limit: 10 ppb
2.6x
EWG's Health Guideline:
0.14 ppb

Total trihalomethanes (TTHMs)

Potential Effect: cancer
This Utility: 36.2 ppb Legal Limit: 80 ppb
241x
EWG's Health Guideline:
0.15 ppb

Trichloroacetic acid

Potential Effect: cancer
This Utility: 7.19 ppb No Legal Limit
72x
EWG's Health Guideline:
0.1 ppb
This Utility: 4.51 ppb No Legal Limit
This Utility: 23.5 ppb Legal Limit: 2000 ppb
EWG's Health Guideline:
700 ppb
This Utility: 0.241 ppb No Legal Limit
EWG's Health Guideline:
0.5 ppb
This Utility: 6.25 ppb No Legal Limit
EWG's Health Guideline:
210 ppb
This Utility: 0.895 ppm Legal Limit: 4 ppm
This Utility: 0.421 ppb No Legal Limit
EWG's Health Guideline:
100 ppb
This Utility: 1.39 ppb No Legal Limit
EWG's Health Guideline:
40 ppb
This Utility: 1.43 ppb No Legal Limit
EWG's Health Guideline:
53 ppb
This Utility: 0.169 ppb No Legal Limit
EWG's Health Guideline:
1500 ppb
This Utility: 0.133 ppb No Legal Limit
EWG's Health Guideline:
21 ppb

Find a Filter

See which water filtration technologies are effective at reducing the contaminants detected in this utility's water supply.

Carbon Filters
Filters 9 contaminants exceeding guidelines (+3 others)

Can reduce the levels of many common contaminants.

Pros
  • Lower upfront cost
  • Reduced maintenance
Cons
  • Does not remove all contaminants
Reverse Osmosis
Filters 12 contaminants exceeding guidelines (+7 others)

Can reduce the levels of many common contaminants.

Pros
  • Most effective
Cons
  • Higher upfront cost
  • Requires more maintenance
  • Wastes water
Other Considerations
Ion Exchange
PROS: Softens hard water, Reduces some contaminants
CONS: Doesn't remove all contaminants
Whole-House Filters
PROS: Useful for reducing radiologicals and TCE
CONS: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants.

Contaminant Activated Carbon Reverse Osmosis Ion Exchange
Contaminants Above Health Guidelines
Bromodichloromethane
Chloroform
Chromium (hexavalent)*
Dibromoacetic acid
Dibromochloromethane
Dichloroacetic acid
Haloacetic acids (HAA5)
Haloacetic acids (HAA9)*
Nitrate
Nitrate and nitrite
Total trihalomethanes (TTHMs)
Trichloroacetic acid
Other Contaminants Detected
1-Butanol
Barium
Bromoform
Chlorate*
Fluoride
Manganese
Molybdenum
Monochloroacetic acid
Strontium*
Vanadium*

Protect your family's health.