Water Utility

Moorhead

Location Moorhead, Minnesota,
MN
Serves 44,583
Source Surface water
PWS ID MN1140008

Overview

Contaminants Detected

Arsenic

Potential Effect: Over Legal Limit
This Utility: 0.767 ppb Legal Limit: 10 ppb
192x
EWG's Health Guideline:
0.004 ppb

Bromate*

Potential Effect: cancer
This Utility: 2.76 ppb Legal Limit: 10 ppb
28x
EWG's Health Guideline:
0.1 ppb

Bromodichloromethane

Potential Effect: cancer
This Utility: 0.148 ppb No Legal Limit
2.5x
EWG's Health Guideline:
0.06 ppb

Chloroform

Potential Effect: cancer
This Utility: 0.806 ppb No Legal Limit
2x
EWG's Health Guideline:
0.4 ppb

Chromium (hexavalent)*

Potential Effect: cancer
This Utility: 0.596 ppb No Legal Limit
30x
EWG's Health Guideline:
0.02 ppb
This Utility: 3.71 ppb No Legal Limit
19x
EWG's Health Guideline:
0.2 ppb

Haloacetic acids (HAA5)

Potential Effect: cancer
This Utility: 3.85 ppb Legal Limit: 60 ppb
39x
EWG's Health Guideline:
0.1 ppb

Haloacetic acids (HAA9)*

Potential Effect: cancer
This Utility: 4.05 ppb No Legal Limit
67x
EWG's Health Guideline:
0.06 ppb

Nitrate

Potential Effect: cancer
This Utility: 0.683 ppm Legal Limit: 10 ppb
4.9x
EWG's Health Guideline:
0.14 ppb

Total trihalomethanes (TTHMs)

Potential Effect: cancer
This Utility: 0.954 ppb Legal Limit: 80 ppb
6.4x
EWG's Health Guideline:
0.15 ppb
This Utility: 0.691 ppm Legal Limit: 4 ppm
This Utility: 78.8 ppb No Legal Limit
This Utility: 0.278 ppb No Legal Limit
EWG's Health Guideline:
100 ppb
This Utility: 2.83 ppb No Legal Limit
EWG's Health Guideline:
40 ppb
This Utility: 0.138 ppb No Legal Limit
EWG's Health Guideline:
53 ppb
This Utility: 2.51 ppt No Legal Limit
EWG's Health Guideline:
1000 ppt
This Utility: 0.099 ppt No Legal Limit
EWG's Health Guideline:
1000 ppt
This Utility: 0.186 ppt No Legal Limit
EWG's Health Guideline:
1000 ppt

Perfluorooctanoic acid (PFOA)

Potential Effect: cancer
This Utility: 0.07 ppt Legal Limit: 4 ppt
EWG's Health Guideline:
0.09 ppt
This Utility: 0.145 ppt No Legal Limit
EWG's Health Guideline:
1000 ppt
This Utility: 0.111 ppb No Legal Limit
EWG's Health Guideline:
1500 ppb
This Utility: 0.655 ppb No Legal Limit
EWG's Health Guideline:
21 ppb

Find a Filter

See which water filtration technologies are effective at reducing the contaminants detected in this utility's water supply.

Carbon Filters
Filters 7 contaminants exceeding guidelines (+6 others)

Can reduce the levels of many common contaminants.

Pros
  • Lower upfront cost
  • Reduced maintenance
Cons
  • Does not remove all contaminants
Reverse Osmosis
Filters 10 contaminants exceeding guidelines (+10 others)

Can reduce the levels of many common contaminants.

Pros
  • Most effective
Cons
  • Higher upfront cost
  • Requires more maintenance
  • Wastes water
Other Considerations
Ion Exchange
PROS: Softens hard water, Reduces some contaminants
CONS: Doesn't remove all contaminants
Whole-House Filters
PROS: Useful for reducing radiologicals and TCE
CONS: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants.

Contaminant Activated Carbon Reverse Osmosis Ion Exchange
Contaminants Above Health Guidelines
Arsenic
Bromate*
Bromodichloromethane
Chloroform
Chromium (hexavalent)*
Dichloroacetic acid
Haloacetic acids (HAA5)
Haloacetic acids (HAA9)*
Nitrate
Total trihalomethanes (TTHMs)
Other Contaminants Detected
Fluoride
Lithium
Manganese
Molybdenum
Monochloroacetic acid
Perfluorobutanoic Acid (PFBA)
Perfluoroheptanoic acid (PFHPA)
Perfluorohexanoic Acid (PFHxA)
Perfluorooctanoic acid (PFOA)
Perfluoropentanoic Acid (PFPeA)
Strontium*
Vanadium*

Protect your family's health.

Don't wait for your utility to improve. Get a free water analysis from AquaPura and find the right filtration system for your home.