Water Utility

Tangipahoa Parish Water District

Location Tangipahoa, Louisiana,
LA
Serves 59,529
Source Groundwater
PWS ID LA1105008

Overview

Contaminants Detected

Arsenic

Potential Effect: Over Legal Limit
This Utility: 0.243 ppb Legal Limit: 10 ppb
61x
EWG's Health Guideline:
0.004 ppb

Chromium (hexavalent)*

Potential Effect: cancer
This Utility: 0.0952 ppb No Legal Limit
4.8x
EWG's Health Guideline:
0.02 ppb
This Utility: 0.885 ppb No Legal Limit
4.4x
EWG's Health Guideline:
0.2 ppb

Haloacetic acids (HAA5)

Potential Effect: cancer
This Utility: 0.952 ppb Legal Limit: 60 ppb
9.5x
EWG's Health Guideline:
0.1 ppb

Haloacetic acids (HAA9)*

Potential Effect: cancer
This Utility: 4.31 ppb No Legal Limit
72x
EWG's Health Guideline:
0.06 ppb

Radium, combined (-226 and -228)

Potential Effect: cancer
This Utility: 0.15 ppb Legal Limit: 5 ppb
2.9x
EWG's Health Guideline:
0.05 ppb

Total trihalomethanes (TTHMs)

Potential Effect: cancer
This Utility: 0.76 ppb Legal Limit: 80 ppb
5.1x
EWG's Health Guideline:
0.15 ppb
This Utility: 0.108 ppb No Legal Limit
This Utility: 10 ppb No Legal Limit
EWG's Health Guideline:
600 ppb

Chloroform

Potential Effect: cancer
This Utility: 0.76 ppb No Legal Limit
EWG's Health Guideline:
0.4 ppb
This Utility: 0.28 ppm Legal Limit: 4 ppm
This Utility: 0.0845 ppb No Legal Limit
This Utility: 14.8 ppb No Legal Limit
This Utility: 15.1 ppb No Legal Limit
EWG's Health Guideline:
100 ppb
This Utility: 1.29 ppb No Legal Limit
EWG's Health Guideline:
40 ppb
This Utility: 0.0632 ppm Legal Limit: 10 ppm
EWG's Health Guideline:
0.14 ppm
This Utility: 0.00531 ppb Legal Limit: 1 ppb
EWG's Health Guideline:
0.3 ppb
This Utility: 0.0232 ppb No Legal Limit
EWG's Health Guideline:
1500 ppb

Trichloroacetic acid

Potential Effect: cancer
This Utility: 0.0633 ppb No Legal Limit
EWG's Health Guideline:
0.1 ppb
This Utility: 0.0693 ppb No Legal Limit
EWG's Health Guideline:
21 ppb

Find a Filter

See which water filtration technologies are effective at reducing the contaminants detected in this utility's water supply.

Carbon Filters
Filters 4 contaminants exceeding guidelines (+4 others)

Can reduce the levels of many common contaminants.

Pros
  • Lower upfront cost
  • Reduced maintenance
Cons
  • Does not remove all contaminants
Reverse Osmosis
Filters 7 contaminants exceeding guidelines (+11 others)

Can reduce the levels of many common contaminants.

Pros
  • Most effective
Cons
  • Higher upfront cost
  • Requires more maintenance
  • Wastes water
Other Considerations
Ion Exchange
PROS: Softens hard water, Reduces some contaminants
CONS: Doesn't remove all contaminants
Whole-House Filters
PROS: Useful for reducing radiologicals and TCE
CONS: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants.

Contaminant Activated Carbon Reverse Osmosis Ion Exchange
Contaminants Above Health Guidelines
Arsenic
Chromium (hexavalent)*
Dichloroacetic acid
Haloacetic acids (HAA5)
Haloacetic acids (HAA9)*
Radium, combined (-226 and -228)
Total trihalomethanes (TTHMs)
Other Contaminants Detected
2-propen-1-ol
Aluminum
Chloroform
Fluoride
Germanium
Lithium
Manganese
Molybdenum
Nitrate and nitrite
Pentachlorophenol
Strontium*
Trichloroacetic acid
Vanadium*