Water Utility

Ruston Water System

Location Ruston, Louisiana,
LA
Serves 22,468
Source Groundwater
PWS ID LA1061017

Overview

Contaminants Detected

Bromodichloromethane

Potential Effect: cancer
This Utility: 3.67 ppb No Legal Limit
61x
EWG's Health Guideline:
0.06 ppb
This Utility: 1.76 ppb No Legal Limit
3.5x
EWG's Health Guideline:
0.5 ppb

Chloroform

Potential Effect: cancer
This Utility: 2.42 ppb No Legal Limit
6x
EWG's Health Guideline:
0.4 ppb
This Utility: 1.88 ppb No Legal Limit
63x
EWG's Health Guideline:
0.03 ppb

Dibromochloromethane

Potential Effect: cancer
This Utility: 4.99 ppb No Legal Limit
50x
EWG's Health Guideline:
0.1 ppb
This Utility: 1.14 ppb No Legal Limit
5.7x
EWG's Health Guideline:
0.2 ppb

Haloacetic acids (HAA5)

Potential Effect: cancer
This Utility: 4.44 ppb Legal Limit: 60 ppb
44x
EWG's Health Guideline:
0.1 ppb

Haloacetic acids (HAA9)*

Potential Effect: cancer
This Utility: 8.57 ppb No Legal Limit
143x
EWG's Health Guideline:
0.06 ppb

Total trihalomethanes (TTHMs)

Potential Effect: cancer
This Utility: 12.8 ppb Legal Limit: 80 ppb
86x
EWG's Health Guideline:
0.15 ppb

Trichloroacetic acid

Potential Effect: cancer
This Utility: 1.2 ppb No Legal Limit
12x
EWG's Health Guideline:
0.1 ppb
This Utility: 3 ppb No Legal Limit
EWG's Health Guideline:
600 ppb
This Utility: 0.11 ppb Legal Limit: 6 ppb
EWG's Health Guideline:
1 ppb
This Utility: 0.0722 ppb No Legal Limit
EWG's Health Guideline:
0.06 ppb

Chromium (hexavalent)*

Potential Effect: cancer
This Utility: 0.0111 ppb No Legal Limit
EWG's Health Guideline:
0.02 ppb
This Utility: 0.062 ppb Legal Limit: 200 ppb
This Utility: 0.16 ppm Legal Limit: 4 ppm
This Utility: 2.01 ppb No Legal Limit
This Utility: 8.33 ppb No Legal Limit
EWG's Health Guideline:
100 ppb
This Utility: 0.221 ppb No Legal Limit
EWG's Health Guideline:
25 ppb
This Utility: 0.0231 ppm Legal Limit: 10 ppm
EWG's Health Guideline:
0.14 ppm

Radium, combined (-226 and -228)

Potential Effect: cancer
This Utility: 0.02 ppb Legal Limit: 5 ppb
EWG's Health Guideline:
0.05 ppb
This Utility: 0.0454 ppb No Legal Limit
EWG's Health Guideline:
1500 ppb
This Utility: 0.027 ppb No Legal Limit
EWG's Health Guideline:
21 ppb

Find a Filter

See which water filtration technologies are effective at reducing the contaminants detected in this utility's water supply.

Carbon Filters
Filters 10 contaminants exceeding guidelines (+3 others)

Can reduce the levels of many common contaminants.

Pros
  • Lower upfront cost
  • Reduced maintenance
Cons
  • Does not remove all contaminants
Reverse Osmosis
Filters 10 contaminants exceeding guidelines (+11 others)

Can reduce the levels of many common contaminants.

Pros
  • Most effective
Cons
  • Higher upfront cost
  • Requires more maintenance
  • Wastes water
Other Considerations
Ion Exchange
PROS: Softens hard water, Reduces some contaminants
CONS: Doesn't remove all contaminants
Whole-House Filters
PROS: Useful for reducing radiologicals and TCE
CONS: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants.

Contaminant Activated Carbon Reverse Osmosis Ion Exchange
Contaminants Above Health Guidelines
Bromodichloromethane
Bromoform
Chloroform
Dibromoacetic acid
Dibromochloromethane
Dichloroacetic acid
Haloacetic acids (HAA5)
Haloacetic acids (HAA9)*
Total trihalomethanes (TTHMs)
Trichloroacetic acid
Other Contaminants Detected
Aluminum
Antimony
Bromochloromethane
Chromium (hexavalent)*
Dalapon
Fluoride
Lithium
Manganese
Monobromoacetic acid*
Nitrate and nitrite
Radium, combined (-226 and -228)
Strontium*
Vanadium*

Protect your family's health.