Water Utility

Storm Lake Water Treatment Plant

Location Storm Lake, Iowa,
IA
Serves 11,431
Source Groundwater
PWS ID IA1178097

Overview

Contaminants Detected

Arsenic

Potential Effect: Over Legal Limit
This Utility: 0.75 ppb Legal Limit: 10 ppb
188x
EWG's Health Guideline:
0.004 ppb

Chlorite

Potential Effect: change in blood chemistry
This Utility: 333.2 ppb Legal Limit: 1000 ppb
6.7x
EWG's Health Guideline:
50 ppb

Chromium (hexavalent)*

Potential Effect: cancer
This Utility: 0.148 ppb No Legal Limit
7.4x
EWG's Health Guideline:
0.02 ppb
This Utility: 0.837 ppb No Legal Limit
4.2x
EWG's Health Guideline:
0.2 ppb

Haloacetic acids (HAA5)

Potential Effect: cancer
This Utility: 1.45 ppb Legal Limit: 60 ppb
15x
EWG's Health Guideline:
0.1 ppb

Haloacetic acids (HAA9)*

Potential Effect: cancer
This Utility: 1.15 ppb No Legal Limit
19x
EWG's Health Guideline:
0.06 ppb

Radium, combined (-226 and -228)

Potential Effect: cancer
This Utility: 0.15 ppb Legal Limit: 5 ppb
3x
EWG's Health Guideline:
0.05 ppb
This Utility: 0.035 ppb Legal Limit: 6 ppb
EWG's Health Guideline:
1 ppb
This Utility: 16.6 ppb Legal Limit: 2000 ppb
EWG's Health Guideline:
700 ppb
This Utility: 260.8 ppb No Legal Limit
EWG's Health Guideline:
210 ppb
This Utility: 0.01 ppb Legal Limit: 100 ppb
This Utility: 0.567 ppm Legal Limit: 4 ppm
This Utility: 110 ppb No Legal Limit
This Utility: 119.5 ppb No Legal Limit
EWG's Health Guideline:
100 ppb
This Utility: 6.95 ppb No Legal Limit
EWG's Health Guideline:
40 ppb
This Utility: 0.532 ppb No Legal Limit
EWG's Health Guideline:
53 ppb

Nitrate

Potential Effect: cancer
This Utility: 0.0275 ppm Legal Limit: 10 ppm
EWG's Health Guideline:
0.14 ppm
This Utility: 0.0459 ppm Legal Limit: 1 ppm
This Utility: 0.05 ppb Legal Limit: 50 ppb
EWG's Health Guideline:
30 ppb
This Utility: 0.4 ppb No Legal Limit
EWG's Health Guideline:
1500 ppb
This Utility: 0.015 ppb Legal Limit: 2 ppb
EWG's Health Guideline:
0.1 ppb

Trichloroacetic acid

Potential Effect: cancer
This Utility: 0.0867 ppb No Legal Limit
EWG's Health Guideline:
0.1 ppb
This Utility: 0.7 ppb No Legal Limit
EWG's Health Guideline:
21 ppb

Find a Filter

See which water filtration technologies are effective at reducing the contaminants detected in this utility's water supply.

Carbon Filters
Filters 4 contaminants exceeding guidelines (+2 others)

Can reduce the levels of many common contaminants.

Pros
  • Lower upfront cost
  • Reduced maintenance
Cons
  • Does not remove all contaminants
Reverse Osmosis
Filters 7 contaminants exceeding guidelines (+13 others)

Can reduce the levels of many common contaminants.

Pros
  • Most effective
Cons
  • Higher upfront cost
  • Requires more maintenance
  • Wastes water
Other Considerations
Ion Exchange
PROS: Softens hard water, Reduces some contaminants
CONS: Doesn't remove all contaminants
Whole-House Filters
PROS: Useful for reducing radiologicals and TCE
CONS: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants.

Contaminant Activated Carbon Reverse Osmosis Ion Exchange
Contaminants Above Health Guidelines
Arsenic
Chlorite
Chromium (hexavalent)*
Dichloroacetic acid
Haloacetic acids (HAA5)
Haloacetic acids (HAA9)*
Radium, combined (-226 and -228)
Other Contaminants Detected
Antimony
Barium
Chlorate*
Chromium (total)
Fluoride
Lithium
Manganese
Molybdenum
Monochloroacetic acid
Nitrate
Nitrite
Selenium
Strontium*
Thallium
Trichloroacetic acid
Vanadium*

Protect your family's health.