Overview
Legal does not necessarily equal safe.
Getting a passing grade from the federal government does not mean the water meets the latest health guidelines.
Legal limits for contaminants in tap water have not been updated in almost 20 years.
The best way to ensure clean tap water is to keep pollution out of source water in the first place.
AquaPura's analysis shows 20 contaminant(s) detected in
Golden State Water Company (GSWC) - Norwalk 's water exceed recommended health guidelines,
though they may be within legal limits set by the EPA.
Contaminants Detected
Exceed Guidelines
20
Other Detected
21
This Utility: 1.97 ppb
No Legal Limit
5.6x
EWG's Health Guideline:0.35 ppb
Potential Effect: Over Legal Limit
↗
This Utility: 0.91 ppb
Legal Limit: 10 ppb
228x
EWG's Health Guideline:0.004 ppb
This Utility: 7.75 ppb
No Legal Limit
129x
EWG's Health Guideline:0.06 ppb
This Utility: 3.58 ppb
No Legal Limit
7.2x
EWG's Health Guideline:0.5 ppb
This Utility: 7.21 ppb
No Legal Limit
18x
EWG's Health Guideline:0.4 ppb
This Utility: 1.35 ppb
No Legal Limit
68x
EWG's Health Guideline:0.02 ppb
This Utility: 2.17 ppb
No Legal Limit
72x
EWG's Health Guideline:0.03 ppb
This Utility: 8.65 ppb
No Legal Limit
86x
EWG's Health Guideline:0.1 ppb
This Utility: 3.9 ppb
No Legal Limit
19x
EWG's Health Guideline:0.2 ppb
This Utility: 36.2 ppb
Legal Limit: 60 ppb
362x
EWG's Health Guideline:0.1 ppb
This Utility: 9.91 ppb
No Legal Limit
165x
EWG's Health Guideline:0.06 ppb
This Utility: 5.53 ppm
Legal Limit: 10 ppb
39x
EWG's Health Guideline:0.14 ppb
This Utility: 2.3 ppm
Legal Limit: 10 ppb
16x
EWG's Health Guideline:0.14 ppb
This Utility: 0.572 ppt
Legal Limit: 10 ppb
572x
EWG's Health Guideline:0.001 ppb
This Utility: 0.183 ppt
Legal Limit: 10 ppb
31x
EWG's Health Guideline:0.006 ppb
This Utility: 2.54 ppt
Legal Limit: 4 ppb
8.5x
EWG's Health Guideline:0.3 ppb
This Utility: 1.38 ppt
Legal Limit: 4 ppb
15x
EWG's Health Guideline:0.09 ppb
This Utility: 27.2 ppb
Legal Limit: 80 ppb
181x
EWG's Health Guideline:0.15 ppb
This Utility: 2.73 ppb
No Legal Limit
27x
EWG's Health Guideline:0.1 ppb
This Utility: 1.3 ppb
Legal Limit: 20 ppb
3x
EWG's Health Guideline:0.43 ppb
This Utility: 0.037 ppb
No Legal Limit
EWG's Health Guideline:3 ppb
This Utility: 0.114 ppb
Legal Limit: 7 ppb
This Utility: 0.00572 ppb
Legal Limit: 5 ppb
EWG's Health Guideline:0.4 ppb
This Utility: 10.8 ppb
No Legal Limit
EWG's Health Guideline:600 ppb
This Utility: 49.2 ppb
Legal Limit: 2000 ppb
EWG's Health Guideline:700 ppb
This Utility: 0.194 ppb
Legal Limit: 5 ppb
EWG's Health Guideline:0.15 ppb
This Utility: 120 ppb
No Legal Limit
EWG's Health Guideline:210 ppb
This Utility: 0.341 ppm
Legal Limit: 4 ppm
This Utility: 13.4 ppb
No Legal Limit
This Utility: 13.2 ppb
No Legal Limit
EWG's Health Guideline:100 ppb
This Utility: 2.71 ppb
No Legal Limit
EWG's Health Guideline:40 ppb
This Utility: 0.567 ppt
No Legal Limit
EWG's Health Guideline:2000 ppt
This Utility: 4.83 ppt
No Legal Limit
EWG's Health Guideline:1000 ppt
This Utility: 0.638 ppt
No Legal Limit
EWG's Health Guideline:1000 ppt
This Utility: 3.67 ppt
No Legal Limit
EWG's Health Guideline:1000 ppt
This Utility: 4.12 ppt
No Legal Limit
EWG's Health Guideline:1000 ppt
This Utility: 0.07 ppb
Legal Limit: 5 ppb
EWG's Health Guideline:0.05 ppb
This Utility: 3.14 ppb
Legal Limit: 50 ppb
EWG's Health Guideline:30 ppb
This Utility: 0.798 ppb
No Legal Limit
EWG's Health Guideline:1500 ppb
This Utility: 0.00513 ppb
Legal Limit: 5 ppb
EWG's Health Guideline:0.4 ppb
This Utility: 2.7 ppb
No Legal Limit
EWG's Health Guideline:21 ppb
Find a Filter
See which water filtration technologies are effective at reducing the contaminants detected in this utility's water supply.
Carbon Filters
Filters 14 contaminants exceeding guidelines (+10 others)
Can reduce the levels of many common contaminants.
Pros
Lower upfront cost Reduced maintenance
Cons
Does not remove all contaminants
Reverse Osmosis
Filters 19 contaminants exceeding guidelines (+18 others)
Can reduce the levels of many common contaminants.
Cons
Higher upfront cost Requires more maintenance Wastes water
Other Considerations
Ion Exchange
PROS: Softens hard water, Reduces some contaminants
CONS: Doesn't remove all contaminants
Whole-House Filters
PROS: Useful for reducing radiologicals and TCE
CONS: Expensive to install and maintain, Risk of bacterial contamination
Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants.
Contaminant
Activated Carbon
Reverse Osmosis
Ion Exchange
1,4-Dioxane
✕
✓
✕
Arsenic
✕
✓
✓
Bromodichloromethane
✓
✓
✕
Bromoform
✓
✓
✕
Chloroform
✓
✓
✕
Chromium (hexavalent)*
✕
✓
✓
Dibromoacetic acid
✓
✓
✕
Dibromochloromethane
✓
✓
✕
Dichloroacetic acid
✓
✓
✕
Haloacetic acids (HAA5)
✓
✓
✕
Haloacetic acids (HAA9)*
✓
✓
✕
Nitrate
✕
✓
✓
Nitrate and nitrite
✕
✓
✓
Perfluorohexane sulfonate (PFHXS)
✓
✓
✕
Perfluorononanoic acid (PFNA)
✓
✓
✕
Perfluorooctane sulfonate (PFOS)
✓
✓
✕
Perfluorooctanoic acid (PFOA)
✓
✓
✕
Total trihalomethanes (TTHMs)
✓
✓
✕
Trichloroacetic acid
✓
✓
✕
1,1-Dichloroethane
✓
✓
✕
1,1-Dichloroethylene
✓
✓
✕
1,2-Dichloroethane
✓
✓
✕
Aluminum
✕
✓
✕
Barium
✕
✓
✓
Benzene
✓
✓
✕
Chlorate*
✕
✕
✕
Fluoride
✕
✓
✕
Lithium
✕
✓
✓
Manganese
✕
✕
✓
Molybdenum
✕
✓
✓
Perfluorobutane sulfonate (PFBS)
✓
✓
✕
Perfluorobutanoic Acid (PFBA)
✓
✓
✕
Perfluoroheptanoic acid (PFHPA)
✓
✓
✕
Perfluorohexanoic Acid (PFHxA)
✓
✓
✕
Perfluoropentanoic Acid (PFPeA)
✓
✓
✕
Radium, combined (-226 and -228)
✕
✓
✓
Selenium
✕
✓
✕
Strontium*
✕
✓
✓
Trichloroethylene
✓
✓
✕
Vanadium*
✕
✕
✓
Protect your family's health.
Don't wait for your utility to improve. Get a free water analysis from AquaPura and find the right filtration system for your home.