Water Utility

Jonesboro Water System

Location Jonesboro, Arkansas,
AR
Serves 79,889
Source Groundwater
PWS ID AR0000124

Overview

Contaminants Detected

Bromodichloromethane

Potential Effect: cancer
This Utility: 0.45 ppb No Legal Limit
7.5x
EWG's Health Guideline:
0.06 ppb
This Utility: 1.86 ppb No Legal Limit
3.7x
EWG's Health Guideline:
0.5 ppb

Chromium (hexavalent)*

Potential Effect: cancer
This Utility: 0.395 ppb No Legal Limit
20x
EWG's Health Guideline:
0.02 ppb
This Utility: 1.24 ppb No Legal Limit
41x
EWG's Health Guideline:
0.03 ppb

Dibromochloromethane

Potential Effect: cancer
This Utility: 0.935 ppb No Legal Limit
9.3x
EWG's Health Guideline:
0.1 ppb

Haloacetic acids (HAA5)

Potential Effect: cancer
This Utility: 1.03 ppb Legal Limit: 60 ppb
10x
EWG's Health Guideline:
0.1 ppb

Haloacetic acids (HAA9)*

Potential Effect: cancer
This Utility: 2.19 ppb No Legal Limit
37x
EWG's Health Guideline:
0.06 ppb

Nitrate

Potential Effect: cancer
This Utility: 0.792 ppm Legal Limit: 10 ppb
5.7x
EWG's Health Guideline:
0.14 ppb
This Utility: 0.53 ppm Legal Limit: 10 ppb
3.8x
EWG's Health Guideline:
0.14 ppb

Radium, combined (-226 and -228)

Potential Effect: cancer
This Utility: 0.19 ppb Legal Limit: 5 ppb
3.7x
EWG's Health Guideline:
0.05 ppb

Total trihalomethanes (TTHMs)

Potential Effect: cancer
This Utility: 7.85 ppb Legal Limit: 80 ppb
52x
EWG's Health Guideline:
0.15 ppb
This Utility: 17 ppb No Legal Limit
EWG's Health Guideline:
210 ppb

Chloroform

Potential Effect: cancer
This Utility: 0.276 ppb No Legal Limit
EWG's Health Guideline:
0.4 ppb
This Utility: 0.769 ppm Legal Limit: 4 ppm
This Utility: 0.578 ppb No Legal Limit
EWG's Health Guideline:
100 ppb
This Utility: 0.0302 ppb No Legal Limit
This Utility: 0.0374 ppb No Legal Limit
EWG's Health Guideline:
1500 ppb
This Utility: 0.295 ppb No Legal Limit
EWG's Health Guideline:
21 ppb
This Utility: 2.99 ppb Legal Limit: 10000 ppb
EWG's Health Guideline:
1800 ppb

Find a Filter

See which water filtration technologies are effective at reducing the contaminants detected in this utility's water supply.

Carbon Filters
Filters 7 contaminants exceeding guidelines (+3 others)

Can reduce the levels of many common contaminants.

Pros
  • Lower upfront cost
  • Reduced maintenance
Cons
  • Does not remove all contaminants
Reverse Osmosis
Filters 11 contaminants exceeding guidelines (+5 others)

Can reduce the levels of many common contaminants.

Pros
  • Most effective
Cons
  • Higher upfront cost
  • Requires more maintenance
  • Wastes water
Other Considerations
Ion Exchange
PROS: Softens hard water, Reduces some contaminants
CONS: Doesn't remove all contaminants
Whole-House Filters
PROS: Useful for reducing radiologicals and TCE
CONS: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants.

Contaminant Activated Carbon Reverse Osmosis Ion Exchange
Contaminants Above Health Guidelines
Bromodichloromethane
Bromoform
Chromium (hexavalent)*
Dibromoacetic acid
Dibromochloromethane
Haloacetic acids (HAA5)
Haloacetic acids (HAA9)*
Nitrate
Nitrate and nitrite
Radium, combined (-226 and -228)
Total trihalomethanes (TTHMs)
Other Contaminants Detected
Chlorate*
Chloroform
Fluoride
Manganese
Naphthalene
Strontium*
Vanadium*
Xylenes (total)

Protect your family's health.