Water Utility

Eufaula Water Works

Location Eufaula, Alabama,
AL
Serves 17,970
Source Groundwater
PWS ID AL0000085

Overview

Contaminants Detected

Arsenic

Potential Effect: Over Legal Limit
This Utility: 0.0571 ppb Legal Limit: 10 ppb
14x
EWG's Health Guideline:
0.004 ppb

Haloacetic acids (HAA5)

Potential Effect: cancer
This Utility: 1.01 ppb Legal Limit: 60 ppb
10x
EWG's Health Guideline:
0.1 ppb

Haloacetic acids (HAA9)*

Potential Effect: cancer
This Utility: 2.88 ppb No Legal Limit
48x
EWG's Health Guideline:
0.06 ppb

Radium, combined (-226 and -228)

Potential Effect: cancer
This Utility: 1 ppb Legal Limit: 5 ppb
20x
EWG's Health Guideline:
0.05 ppb

Total trihalomethanes (TTHMs)

Potential Effect: cancer
This Utility: 15.3 ppb Legal Limit: 80 ppb
102x
EWG's Health Guideline:
0.15 ppb
This Utility: 26.2 ppb No Legal Limit
EWG's Health Guideline:
600 ppb
This Utility: 0.0343 ppb Legal Limit: 6 ppb
EWG's Health Guideline:
1 ppb
This Utility: 1.1 ppb Legal Limit: 2000 ppb
EWG's Health Guideline:
700 ppb
This Utility: 0.0271 ppb Legal Limit: 4 ppb
EWG's Health Guideline:
1 ppb
This Utility: 0.0286 ppb Legal Limit: 5 ppb
EWG's Health Guideline:
0.04 ppb

Chromium (hexavalent)*

Potential Effect: cancer
This Utility: 0.00418 ppb No Legal Limit
EWG's Health Guideline:
0.02 ppb
This Utility: 1.14 ppb Legal Limit: 100 ppb
This Utility: 0.512 ppm Legal Limit: 4 ppm
This Utility: 0.679 ppb No Legal Limit
This Utility: 0.966 ppb No Legal Limit
EWG's Health Guideline:
100 ppb

Nitrate

Potential Effect: cancer
This Utility: 0.00212 ppm Legal Limit: 10 ppm
EWG's Health Guideline:
0.14 ppm
This Utility: 0.00212 ppm Legal Limit: 10 ppm
EWG's Health Guideline:
0.14 ppm
This Utility: 0.12 ppb Legal Limit: 50 ppb
EWG's Health Guideline:
30 ppb
This Utility: 0.0167 ppb No Legal Limit
EWG's Health Guideline:
1500 ppb
This Utility: 0.0214 ppb Legal Limit: 2 ppb
EWG's Health Guideline:
0.1 ppb
This Utility: 0.11 ppb No Legal Limit
EWG's Health Guideline:
21 ppb

Find a Filter

See which water filtration technologies are effective at reducing the contaminants detected in this utility's water supply.

Carbon Filters
Filters 3 contaminants exceeding guidelines (+1 others)

Can reduce the levels of many common contaminants.

Pros
  • Lower upfront cost
  • Reduced maintenance
Cons
  • Does not remove all contaminants
Reverse Osmosis
Filters 5 contaminants exceeding guidelines (+14 others)

Can reduce the levels of many common contaminants.

Pros
  • Most effective
Cons
  • Higher upfront cost
  • Requires more maintenance
  • Wastes water
Other Considerations
Ion Exchange
PROS: Softens hard water, Reduces some contaminants
CONS: Doesn't remove all contaminants
Whole-House Filters
PROS: Useful for reducing radiologicals and TCE
CONS: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants.

Contaminant Activated Carbon Reverse Osmosis Ion Exchange
Contaminants Above Health Guidelines
Arsenic
Haloacetic acids (HAA5)
Haloacetic acids (HAA9)*
Radium, combined (-226 and -228)
Total trihalomethanes (TTHMs)
Other Contaminants Detected
Aluminum
Antimony
Barium
Beryllium
Cadmium
Chromium (hexavalent)*
Chromium (total)
Fluoride
Germanium
Manganese
Nitrate
Nitrate and nitrite
Selenium
Strontium*
Thallium
Vanadium*

Protect your family's health.

Don't wait for your utility to improve. Get a free water analysis from AquaPura and find the right filtration system for your home.